ISI / ISO / CE (As Applicable)
Portable Dry Chemical Powder Based (SP Type) Fire Extinguisher
AMTEX Stored Pressure (SP) ABC dry chemical powder extinguisher for Class A, B, C and electrically started fires. MAP mono ammonium phosphate powder with controllable discharge and multiple size options.
Portable Dry Chemical Powder Based (SP Type) Fire Extinguisher
Portable Dry Chemical Powder Based (Stored Pressure Type) Fire Extinguisher
An ABC powder fire extinguisher is a multi-purpose extinguisher and is one of the most common extinguishers to have on hand.
A powder extinguisher sprays a very fine chemical powder composed most commonly of monoammonium phosphate (MAP). This blankets the fire and suffocates it.
Powder extinguishers are effective for Class A, B and C fires. Since powder is not an electrical conductor and can break the chain reaction in liquid or gas fires, it is also suitable for electrically started fires.
- Suitable for A, B, C and electrically started fires
- IS:15683 (2018) with latest amendments
- MAP Mono Ammonium Phosphate dry chemical powder
- BIS Approved, ISI & CE marked
- Hydraulically tested and anti-corrosive treated
- High quality Pure Polyester (PP) powder coating
- Brass chrome plated valve with squeeze operation
- Unique Gauge Testing System (UGTS) and controllable discharge
- Rubber braided hose (flexible & crack resistant)
- Conformity standard: IS:15683:2018 (Latest)
Available sizes: 1Kg, 2Kg, 4Kg, 6Kg, 9Kg
Refilling must be done by Manufacturer or Authorised Skilled Agent. Technical specifications subject to change due to continuous improvement.
-
Multi-Class Protection
Effective on Class A, B, C and electrically started fires
-
MAP ABC Powder
Mono Ammonium Phosphate powder blankets and suffocates the fire
-
UGTS + Pressure Gauge
Gauge and UGTS help verify readiness and enable controllable discharge
-
Squeeze Operation
Brass chrome plated valve with easy squeeze activation
-
Certified & Tested
BIS approved, ISI & CE marked; hydraulically tested & anti-corrosive treated
Works on
Recommended For
- Schools
- Offices & Banks
- Hotels
- Restaurants
- Electrical Equipment Rooms
- Server Rooms
- Parking Garages
- Repair Workshops
- Construction Sites
- Propane Filling & Storage
- Welding Areas
- Machine Operations
Technical & Performance Data
| Parameter | AS/01 & AS/02 | AS/04 | AS/06 | AS/09 |
|---|---|---|---|---|
| CAPACITY | 1KG/2KG | 4KG | 6KG | 9KG |
| EXTINGUISHING AGENT | ABC POWDER | ABC POWDER | ABC POWDER | ABC POWDER |
| PROPELLANT | NITROGEN GAS (As per IS:1747) | NITROGEN GAS (As per IS:1747) | NITROGEN GAS (As per IS:1747) | NITROGEN GAS (As per IS:1747) |
| APPLICABLE ON FIRES | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire | A, B, C, & Electrical Started Fire |
| OPERATING TEMPERATURE | -30 C to +60 C | -30 C to +60 C | -30 C to +60 C | -30 C to +60 C |
| FIRE RATING | MIN 1A& 34B | MIN 3A& 55B | MIN 3A& 89B | MIN 4A& 144B |
| HYDROSTATIC TEST PRESSURE | 35 BAR | 35 BAR | 35 BAR | 35 BAR |
| BURST PRESSURE | MIN 55 BAR | MIN 55 BAR | MIN 55 BAR | MIN 55 BAR |
| WORKING PRESSURE | 15 BAR | 15 BAR | 15 BAR | 15 BAR |
| IMPACT TEST | PASSED | PASSED | PASSED | PASSED |
| PRESSURE CYCLING TEST | PASSED | PASSED | PASSED | PASSED |
| TAPPING TEST | PASSED | PASSED | PASSED | PASSED |
| INTERMITTENT DISCHARGE TEST | PASSED | PASSED | PASSED | PASSED |
| COATING | EPOXY POWDER COATING | EPOXY POWDER COATING | EPOXY POWDER COATING | EPOXY POWDER COATING |
| VALVE / CAP CONSTRUCTION | FORGING AND MACHINING | FORGING AND MACHINING | FORGING AND MACHINING | FORGING AND MACHINING |
| DISCHARGE MECHANISM | SQUEEZE GRIP/THUMB TRIGGERED | SQUEEZE GRIP/THUMB TRIGGERED | SQUEEZE GRIP/THUMB TRIGGERED | SQUEEZE GRIP/THUMB TRIGGERED |
| METHOD OF OPERATION | EASY ACTIVATION | EASY ACTIVATION | EASY ACTIVATION | EASY ACTIVATION |
| BODY THICKNESS | AS PER IS:15683 | AS PER IS:15683 | AS PER IS:15683 | AS PER IS:15683 |
| HELIUM LEAK DETECTION TESTING | YES | YES | YES | YES |
| LEAKAGE TEST (Latest) | YES | YES | YES | YES |
| HEIGHT (APPROX.) | Approx. 335mm/365mm | Approx. 440 mm | Approx. 460 mm | Approx. 550 mm |
| GROSS WEIGHT (APPROX.) | Min. 2.100 Kg/Min. 3.200 Kg | Min. 6.200Kg | Min. 8.400 Kg | Min 12.300 Kg |
| AVERAGE DISCHARGE TIME(MED) | MIN 9 SEC | MIN 13 SEC | MIN 13 SEC | MIN 13 SEC |
| AVERAGE RANGE OF THROW | 1-2 MTR. | 2-3 MTR. | 2-5 MTR. | 2-6 MTR. |
| AVERAGE % DISCHARGE | MIN 90% | MIN 90% | MIN 90% | MIN 90% |
| MOUNTING BRACKET | YES | YES | YES | YES |
| PRESSURE GAUGE | YES | YES | YES | YES |
| READYNESS OF WORKING | SHOWING | SHOWING | SHOWING | SHOWING |
| HOSE ASSEMBLIES | (ONLY NOZZLE) | YES (MORE THAN 400 MM) | YES (MORE THAN 400 MM) | YES (MORE THAN 400 MM) |
| SAFETY LOCKING DEVICE | YES(20 N TO 100 N) | YES(20 N TO 100 N) | YES(20 N TO 100 N) | YES(20 N TO 100 N) |
| CONFORMING STANDARDS | IS:15683(LATEST) | IS:15683(LATEST) | IS:15683(LATEST) | IS:15683(LATEST) |
| NABL LAB APPROVAL (BIS APPROVED LAB) | YES | YES | YES | YES |
| APPROVALS | BIS,CE,EN & ISO | BIS,CE,EN & ISO | BIS,CE,EN & ISO | BIS,CE,EN & ISO |
| REFILLING SCHEDULE | AS PER IS:2190 | AS PER IS:2190 | AS PER IS:2190 | AS PER IS:2190 |