Portable Mist (Stored Pressure Type) Fire Extinguisher
[Stainless Steel]

Product Overview-Product Features
Smart Fire Protection – Safe for People, Electronics & the Environment
Our Portable Mist Fire Extinguisher uses cutting-edge fine mist technology to suppress fires rapidly, without leaving behind any mess. Built in a stored pressure configuration, it is always ready for quick and hassle-free operation.
This advanced AMTEX mist extinguisher is highly effective on Class A (solid combustibles), Class B (flammable liquids), Class C (flammable gases), and Class F (cooking oils and fats) fires. It is also safe for use electrically started fires from a safe distance. Its versatile performance makes it ideal for a wide range of residential, commercial, industrial, and institutional environments.
Key Highlights:
- Stored Pressure Type – Always ready for immediate action
- Fine Mist Technology – Cools and suffocates the fire without damage
- No Residue – Safe for electronics, documents & appliances
- Eco-Safe & Non-Corrosive – Harmless to people and the environment
- Durable Build – Rust-resistant body ensures long life (for SS body construction)
- Easy to Use – Lightweight and intuitive design for quick response
Works on:

Class-A

Class-B

Class-C

Class-F

Electrically started fires
- Recommended For:
- Homes & Residential Kitchens
- Modular & Commercial Kitchens
- Offices & Corporate Buildings
- Restaurants, Cafeterias & Food Courts
- Hospitals, Clinics & Laboratories
- Schools, Colleges & Coaching Centers
- Hotels, Guest Houses & Hostels
- Server Rooms & IT Facilities
- Museums, Libraries & Archives
- Retail Stores & Shopping Malls
- Electrical Panels & Battery Rooms
- Public Transport Vehicles & Emergency Vans
- Places of Worship & Community Halls
- Sensitive Installations & Clean Rooms
- Government Buildings & Control Rooms
- High-rise Apartments & Society Basements
- Daycare Centres & Senior Living Homes
- Cold Storages & Packaging Areas
- Etc.
- World class quality: Comes with ISO 9001 and CE certification, and conforms to ISI standards. Comprehensive Helium Tests and Leak Tests also guarantee that the products you buy are manufactured according to the world's most stringent quality standards.
- Available Sizes:
1L, 2L, 3L, 4L, 6L, 9L
- Available varients:
Stainless Steel Polish and Regular Fire Red
Technical & Performance Data :
MODEL/MAKE | WATMIST(SP)/2 | WATMIST(SP)/4 | WATMIST(SP)/6 | WATMIST(SP)/9 |
---|---|---|---|---|
CAPACITY | 2 Ltrs. | 4 Ltrs. | 6 Ltrs. | 9 Ltrs. |
EXTINGUISHING AGENT | DEIONISED WATER | DEIONISED WATER | DEIONISED WATER | DEIONISED WATER |
PROPELLANT | NITROGEN GAS (As per IS:1747) | NITROGEN GAS (As per IS:1747) | NITROGEN GAS (As per IS:1747) | NITROGEN GAS (As per IS:1747) |
APPLICABLE ON FIRES | APPLICABLE ON FIRES | APPLICABLE ON FIRES | APPLICABLE ON FIRES | APPLICABLE ON FIRES |
OPERATING TEMPERATURE | +5 °C to +60 °C | +5 °C to +60 °C | +5 °C to +60 °C | +5 °C to +60 °C |
FIRE RATING | V | |||
HYDROSTATIC TEST PRESSURE | 35 BAR | 35 BAR | 35 BAR | 35 BAR |
BURST PRESSURE | MIN 55 BAR | MIN 55 BAR | MIN 55 BAR | MIN 55 BAR |
WORKING PRESSURE | 15 BAR | 15 BAR | 15 BAR | 15 BAR |
IMPACT TEST | PASSED | PASSED | PASSED | PASSED |
PRESSURE CYCLING TEST | PASSED | PASSED | PASSED | PASSED |
TAPPING TEST | PASSED | PASSED | PASSED | PASSED |
INTERMITTENT DISCHARGE TEST | PASSED | PASSED | PASSED | PASSED |
COATING | EPOXY POWDER COATING | EPOXY POWDER COATING | EPOXY POWDER COATING | EPOXY POWDER COATING |
VALVE / CAP CONSTRUCTION | FORGING AND MACHINING | FORGING AND MACHINING | FORGING AND MACHINING | FORGING AND MACHINING |
DISCHARGE MECHANISM | SQUEEZE GRIP Controllable | SQUEEZE GRIP Controllable | SQUEEZE GRIP Controllable | SQUEEZE GRIP Controllable |
METHOD OF OPERATION | EASY ACTIVATION | EASY ACTIVATION | EASY ACTIVATION | EASY ACTIVATION |
BODY THICKNESS | AS PER IS:15683 | AS PER IS:15683 | AS PER IS:15683 | AS PER IS:15683 |
CAST ANALYSIS OF THE BODY | As Per IS:15683(Latest) | As Per IS:15683(Latest) | As Per IS:15683(Latest) | As Per IS:15683(Latest) |
HELIUM LEAK DETECTION TESTING | YES | YES | YES | YES |
LEAKAGE TEST(Latest) | YES | YES | YES | YES |
AVERAGE DISCHARGE TIME(MED) | MIN 9 SEC | MIN 13 SEC | MIN 13 SEC | MIN 13 SEC |
AVERAGE RANGE OF THROW | 1-2 MTR. | 2-3 MTR. | 2-5 MTR. | 2-6 MTR. |
AVERAGE % DISCHARGE | MIN 85% | MIN 85% | MIN 85% | MIN 85% |
MOUNTING BRACKET | YES | YES | YES | YES |
PRESSURE GAUGE | YES | YES | YES | YES |
READYNESS OF WORKING | SHOWING | SHOWING | SHOWING | SHOWING |
HOSE ASSEMBLIES | (ONLY AMTEX MIST NOZZLE) | YES (MORE THAN 400 MM with AMTEX MIST NOZZLE) | YES (MORE THAN 400 MM with AMTEX MIST NOZZLE) | YES (MORE THAN 400 MM with AMTEX MIST NOZZLE) |
SAFETY LOCKING DEVICE | YES(20 N TO 100 N) | YES(20 N TO 100 N) | YES(20 N TO 100 N) | YES(20 N TO 100 N) |
CONFORMING STANDARDS | IS:15683(LATEST) | IS:15683(LATEST) | IS:15683(LATEST) | IS:15683(LATEST) |
NABL LAB APPROVAL | YES | YES | YES | YES |
REFILLING SCHEDULE | AS PER IS:2190 | AS PER IS:2190 | AS PER IS:2190 | AS PER IS:2190 |
- It is mandatory for the extinguisher to be refilled by Manufacturer or Authorised Skilled Agent.